Technical data Thermo Top Evo
Heater | Operation | Thermo Top Evo - B | Thermo Top Evo - D | |||
---|---|---|---|---|---|---|
|
| 5 kW | 4 kW | 5 kW | 4 kW | |
ECE approval mark |
| R122 E1 00 0258 (heating) R10 E1 04 5627 (EMC) | ||||
Design |
| Water heater with evaporator burner | ||||
Heat flow | Maximum heating capacity Minimum heating capacity | 5.0 kW 2.8 kW | 4.0 kW 2.8 kW | 5.0 kW 2.5 kW / 1.8 kW * | 4.0 kW 2.5 kW | |
Fuel |
| E0-E10 according to EN 228 E85 according to DIN 51625 | B7 according to EN 590 DIN EN 15940 | |||
Fuel consumption | Maximum heating capacity
| 0.705 l/h
| 0.560 l/h
| 0.620 l/h (5 kW)
| 0.495 l/h
| |
Rated voltage |
| 12 Volt | ||||
Operating voltage range |
| 10 to 16.5 Volt | ||||
Rated power consumption +/- 10% without coolant pump and vehicle blower | Maximum heating capacity Minimum heating capacity | 31W 14W | 21W 14W | 31W 12 W (2.5 kW), | 21W 12W | |
Ambient temperature in heating mode (installation situation) |
| |||||
Heater | -40 °C to +60 °C | -40 °C to +60 °C | ||||
Fuel pump arctic diesel |
|
-40 °C to +30 °C | ||||
Ambient storage temperature |
| |||||
Heater | -40 °C to +125 °C | |||||
Control unit | -40 °C to +125 °C | |||||
Fuel pump | -40 °C to +90 °C | |||||
Perm. operating pressure |
| 2.5 bar | ||||
Capacity of the heat exchanger |
| 0.075 l | ||||
Minimum volume in coolant circuit |
| 2.0 + 0.5 l | ||||
Minimum volume flow for heater |
| 200 l/h | ||||
CO2 in exhaust gas (permitted function range) |
| functional range approx. 8-12 % | ||||
Dimensions of heater without attached parts. Also see Fig 2 (tolerance ± 3 mm) |
| Length 218 mm | ||||
Weight |
| 2.2 kg |
* Thermo Top Evo RV